Three Phase String PV Inverter HRV 225 KTL-HV


Category:


keyword:

Inverter


● 1500 V DC Voltage 
● 12 Road Number of MPPT roads 
● 99.03% Maximum efficiency
● 98.55% China Efficiency
● IP66 Protection level

 

Technical Data


Efficient Power Generation Saving Investment Safe and Reliable Wise and Friendly
- Maximum efficiency 99.03%, 
 China efficiency 98.55%;
- 12-way MPPT design, complex application 
 scenarios to improve power generation;
- Integrated PID protection and repair, to imp-
 rove system power generation. 
- Support converging two strings to one input
 , saving the cost of DC cables;
- Support alumium aire access, saving the 
 cost of AC cables;
- Support PLC communication, saving the 
 cost of communication cables and cons-
 truction. 
- IP66 protection rating, C5 anti-corrosion
 rating, suitable for all kinds of the severe
 environment;
- IP 68 intelligent fan cooling, low tempe-
 rature rising, long life.
- String detection and I-V scan, precisely lo-
 cate the abnormal string;
- AC/DC dual power supply redundancy de-
 sign, 24-hour status monitoring;
- Active full load power factor up to 0.99, su

HRV225KTL-HV

Efficiency

Maximum  Efficiency 99.03%
China Efficiency 98.55%

Input

Max. input voltage

1500V

Max. number of input circuits

24

Number of MPPT

12

Max. input current per MPPT

360A (12*30A)

Max.short-circuit current per MPPT

600A (12*50A)

No. of MPPT input strings

2

MPPT yoltage range

500V ~ 1500V

FulHoad MPPT operating valtage range

860V ~ 1300V

Rated input voltage

1080V

Output

Rated output power

225kW

Max. apparent power

247.5kVA

Max. active power (cosφ=1)

247.5kW

Rated output voltage

3*462V/800V+PE

Output voltage frequency

50Hz/60Hz

Max. output current

178.7A

Power factor

>0.99(0.8 over.. .0.8 lagging)

DC   component

<0.5%In

Max. total harmonic distortion

<3%

Protection

Input DC switch

support

Anti-islanding protection

support

Output overcurrent protection

support

Input reverse connection protection

support

String fault detection

support

DC surge protection

Typell

AC surge protection

Type ll

Insulation impedance detection

support

Residual current monitoring

support

Anti-PID function

Optional

General parameters

Dimensions   (W"H*D)

1110*764*364mm

Weight

110Kg

Operating temperature

 25°C~60°C

Cooling  method

Intelligent forced air cooling

Relative humidity

0~100%

Protection level

IP66

Communication method

RS485/GPRS/WIFI/4G/5G

 Input terminal

MC4/Amphenol H4

 Output terminal

OT terminal

Self-consumption of Electricity at night

<=5W

Standard

NB/T 32004

Online Message


%{tishi_zhanwei}%

 ©2022 Hangzhou Seetek New Energy Sci-tech Co.,LtD  | SEO   Powered by:www.300.cn