Solar Plus Storage System
Category:
keyword:
Energy Storage System
| Bidirectional AC / DC converter canrealize the bidirectional conversionfromDCtoACandACtoDC.Itcannot only convert AC to DC to chargebattery, but also convert DC to AC tosupply power to load or feed back topower grid. |
| The system mainly consists of safe,effcient and long-life lithium ironphosphate cells, which are connectedin series to form battery modules, andmultiple modules are connected inseries to form battery clusters. |
| Air Conditioning (HVAC) system isconfigured to maintained an optimaltemperature to maximize energysystem operational life and reliability. |
| The core components of the systemcan effectively protect the batteryfrom overcharge, overdischarge andover-current. At the same time, thebalanced management of the cellscan ensure the safe, reliable andefficient operation of the wholesystem. |
| System operation data monitoring,operation strategy management,historical data record, system statusrecord, etc. |
| IP54 design to adapt to moreapplication scenarios. |
Technical Data

| Parameter | GRES-75-50 | GRES-150-100 | GRES -225-150 | GRES-300-200 |
| AC parameters (grid connected) | ||||
| Rated output power (kW) | 50 | 100 | 150 | 200 |
| Max output power (kW) | 55 | 110 | 165 | 220 |
| Rated grid voltage (V) | 3W +N+PE, 380 | |||
| Grid vola ge range | -15%6~+10% | |||
| Rated grid fequency (Hz) | 50/60 | |||
| G rid frequency range (Hz) | 土2 | |||
| C urrent wave form distorion rate | <3%(Rated voltage) | |||
| DC component | <0.5%In | |||
| Power factor | >0.99(Rated voltage) | |||
| Power fa ctor adjus ta ble range | 1(lead~1(lag) | |||
| Overload capacity | 105%]: continuous operation; (105% - 120%]: 10min; 120%); stop operation | |||
| AC parameters (off grid) | ||||
| Rated output power (kW) | 50 | 100 | 150 | 200 |
| Max output power (kW) | 55 | 110 | 165 | 220 |
| Rated grid voltage (V) | 3W+N+PE, 380 | |||
| Current wa veform dis tortion rate | <3%(Linear Load) | |||
| Rated frequency (Hz) | 50/60 | |||
| Overbad capacity | 105%]: continuous operation; (105%一120%]: 10min; 120%); stop operation | |||
| Battery | ||||
| Batery type | Lithium iron phos phate | |||
| Energy of each module(kWh) | 5.12 | |||
| Module qty | 15 | 30 | 45 | 60 |
| Total power (kWh) | 76.8 | 153.6 | 230.4 | 307.2 |
| Running Time (h) | 1.5(Optonal by C ha nging module qty) | |||
| Cycle life | 25℃0.5C/0.5C 100% DODE OL 80% ≥4000s | |||
| System efficiency | ||||
| Max eflciency | 95% | |||
| Protection | ||||
| DC S witch | YES | |||
| AC switch | YES | |||
| Grid monitoring | YES | |||
| Surge protection | DC /AC 2nd level | |||
| Basic Para meters | ||||
| Dimension (W*D*H) (mm) | 1680*1500*1700 | 1680* 2270*1700 | 1680* 3050*1700 | 1680* 3830*2300 |
| Weight (kg) | 1395 | 2470 | 3545 | 4620 |
| Isola ted tra ns former | No | |||
| Protection | STS | |||
| Working temperature | -20~55℃(>45℃derating) | |||
| Rela tive humidity | 0~95% ( (no condens ing) | |||
| Cooling | Intelligent air cooling (intellgent heating optonal) | |||
| Max working alitude(m) | 4000(>2000 derating) | |||
| Display | Touch screen | |||
| Communica tion | RS485、CAN、L AN | |||
| C ommunica tion Protocol | ||||